    TZYIW-100F Infrared Temperature Measurement Window

    Used to detect and monitor the temperature of heating components such as circuit breaker contacts, current transformer contacts, high-voltage switch contacts, and busbar connection points of power equipment in special sealed environments.
    Add time:2026-09-08
    Page views:86
    Dial +86-312-3156390 / 3155390
    Product Overview

    The infrared window for temperature measurement, also known as an infrared observation window, infrared window, or infrared window, is an optical window that can transmit infrared, ultraviolet, and visible light. It uses an infrared thermal imaging instrument to scan the internal connection positions of high-voltage electrical appliances using infrared radiation. High voltage equipment generally used in sealed environments with voltage levels of 6KV and above (and occasionally 380V voltage levels) is mainly used to detect and monitor the temperature of heating components such as circuit breaker contacts, current transformer contacts, high-voltage switch contacts, and busbar connection points of power equipment in special sealed environments.

    When traditional temperature measurement methods such as thermocouples, wireless temperature probes, fiber optic temperature measurement, and grating temperature measurement are unable to measure the temperature of the heat generating components of power equipment in the sealed environment, or when temperature measurement can be achieved but the electronic equipment used in this temperature measurement method has a high probability of causing secondary fault points after a period of use, using an infrared temperature measurement window for temperature measurement becomes a good choice. The infrared temperature measurement window device is installed on the front and rear panels of the cabinet, transformer box, transformer junction box, GIS high-voltage equipment, motor control center, terminal box, and motor junction boxes of power plant fans, pumps, coal mills, and other electrical equipment. On site power operation and maintenance personnel can use infrared temperature measurement instruments such as infrared imagers and infrared thermometers to achieve real-time detection of infrared imaging and temperature measurement of heat generating components of power equipment in a sealed environment under live operation.

    Features

    The explosion-proof infrared temperature measurement window products have several specifications, including TZYIW-75F, TZYIW-80F, TZYIW-100F, etc. The crescent shaped protective cover of this product reduces the diameter of the cabinet opening, and has an internally and externally synchronized movable metal explosion-proof plate, which enhances the explosion-proof performance. In the event of arc light, it can ensure that the product itself is not affected by performance and can also ensure on-site operation and maintenance personnel.

    Specifications
    Model SpecificationStructureCrystal diameter (mm)Visible Diameter (mm)Opening Diameter (mm)Grounding Conduction StructureOpening MethodFlange Main‑body Mounting DirectionBuilt‑in Metal Explosion‑proof Plate
    TZYIW‑60PFlat Standard Type6055.575OptionalScrew OpeningOutside‑in/
    TZYIW‑75PFlat Standard Type7570.590OptionalScrew OpeningOutside‑in/
    TZYIW‑80PFlat Standard Type8075.595OptionalScrew OpeningOutside‑in/
    TZYIW‑100PFlat Standard Type10095.5115OptionalScrew OpeningOutside‑in/
    TZYIW‑60SFlat Safety Type6055.575OptionalThread OpeningOutside‑in/
    TZYIW‑75SFlat Safety Type7570.590OptionalThread OpeningOutside‑in/
    TZYIW‑80SFlat Safety Type8075.595OptionalThread OpeningOutside‑in/
    TZYIW‑100SFlat Safety Type10095.5115OptionalThread OpeningOutside‑in/
    TZYIW‑75GFlat Quick‑safety Type7570.590OptionalMagnet Lock + Screw OpeningOutside‑in/
    TZYIW‑80GFlat Quick‑safety Type8075.595OptionalMagnet Lock + Screw OpeningOutside‑in/
    TZYIW‑100GFlat Quick‑safety Type10095.5115OptionalMagnet Lock + Screw OpeningOutside‑in/
    TZYIW‑75QFlat type coagulation remover7570.5100OptionalMagnet Lock OpeningOutside‑in/
    TZYIW‑80QFlat type coagulation remover8075.5105OptionalMagnet Lock OpeningOutside‑in/
    TZYIW‑100QFlat type coagulation remover10095.5125OptionalMagnet Lock OpeningOutside‑in/
    TZYIW‑75FFlat Explosion‑proof Type7570.5105OptionalMagnet Lock OpeningOutside‑inYes
    TZYIW‑80FFlat Explosion‑proof Type8075.5110OptionalMagnet Lock OpeningOutside‑inYes
    TZYIW‑100FFlat Explosion‑proof Type10095.5130OptionalMagnet Lock OpeningOutside‑inYes
    TZYIW‑100XRotating full rotation transformation10095.5130OptionalMagnet Lock OpeningOutside‑in/
    TZYIW‑100XRotary Semi‑rotary Type10095.5130OptionalMagnet Lock OpeningOutside‑in/
    • Registered address: Room 302, Building 6, Baoding Zhongguancun Digital Economy Industrial Park, 777 Lixing Street, Gaokai District, Baoding City, Hebei Province

    • Mobile:+86-152-000-51135 (working hours)
                  +86-137-2296-5163 (off hours)
                  +86-136-6330-3815
      Online:+86-312-3156390/3155390

    • Marketing internal email: tzydq_yxb@163.com
      Technical Email: tzydq_jsb@163.com

    Copyright © Hebei Taizhongyan Electrical Equipment Technology Co., Ltd https://www.tzydq.com/ All Rights Reserved  Record number:冀ICP备13014722号-1    Friendship links: Optoelectronic Materials Division   Distribution Monitoring Division  
    HomeTelProduct