    TZY-ZGF1000 Ordinary DC High Voltage Generator Series

    The DC high voltage generator adopts PWM high-frequency pulse width modulation technology for closed-loop adjustment, with a small pulsation factor and fast and reliable protection circuit. The display screen adopts a backlight source and a wide temperature LCD display screen, which can clearly display data in strong light and darkness.
    Add time:2022-02-15
    Page views:1
    Dial +86-312-3156390 / 3155390
    Product Overview

    The DC high-voltage generator adopts PWM high-frequency pulse width modulation technology for closed-loop adjustment, with high voltage stability, small ripple factor, and fast and reliable protection circuit. The display screen adopts green backlight and wide temperature LCD display, which can clearly display data in strong light and darkness. The high-voltage components use DuPont's new filling material, which makes the product performance more stable and reliable. The product is widely used in power generation and supply departments, transmission and transformation engineering companies, and large-scale factories and mines as a preventive experiment and research institute for DC high-voltage stabilized power supply.

    Features

    1. Adopting PWM high-frequency pulse width modulation technology for closed-loop adjustment, it has high voltage stability, small ripple factor, and fast and reliable protection circuit. It can withstand direct discharge of large capacitance test samples to ground, and the whole machine is small in size, light in weight, and convenient for field use.

    2. Full range linear smooth adjustment of voltage, with voltage regulation accuracy better than 0.1%; Voltage measurement accuracy of 0.5%, resolution of 0.1kV; current measurement accuracy of 0.5%, resolution: control box 1 µ A, anti surge ammeter 0.1 µ A.

    3. The power supply is AC 220V (AC220V ± 10%, 50Hz ± 1%), with a ripple factor of less than 0.5%. It can be used 24/7 at the work site.

    4. The high-voltage doubler adopts DuPont material all solid packaging, overcoming the inconvenience caused by air and oil filled equipment. Wide base light quality outer tube, stable placement, easier maintenance.

    5. 75% MOA voltage conversion button, easy and convenient to test lightning arrester.

    6. Equipped with overvoltage setting function, the adjustment process displays the overvoltage value; Equipped with overvoltage, overcurrent, and short-circuit discharge protection functions.

    7. It has complete protection functions for disconnection and non-zero potential startup, ensuring that operators and test samples are protected at all times. The overall design of the shock resistant control box includes a simple and clear panel design and sound prompts for operation.

    Specifications
    Voltage kV
    Current mA
    Control CabinetHigh‑Voltage Multiplier Unit
    Rated VoltageOverall Dimensions (mm)Weight (kg)Overall Dimensions (mm)Weight (kg)
    60/2‑1060kV310 * 250 * 2305kg470 * 260 * 2206kg
    80/2‑1080kV310 * 250 * 2306kg490*260*2208kg
    100/2‑10100kV310 * 250 * 2306kg550*260*2208kg
    120/2‑10120kV310 * 250 * 2307kg600 * 260 * 22010kg
    200/2‑5200kV310 * 250 * 2308kg1000 * 280 * 27020kg
    250/2‑5250kV310 * 250 * 2308kg1130 * 290* 27020kg
    300/2‑5300kV310 * 250 * 2309kg1300 * 290 * 27022kg
    350/2‑5350kV310 * 250 * 2309kg1370 * 290 * 27024kg
    Output PolarityNegative voltage polarity, zero‑voltage start, linearly continuously adjustable
    Power Supply50Hz AC220V±10%
    Voltage Measurement Accuracy±0.5% ±2 digits, minimum resolution up to 0.1kV, measuring range (10% ~ 110% of full‑scale range)
    Current Measurement Accuracy±0.5% ±2 digits, minimum resolution: 0.1µA for shock‑resistant ammeter, 1µA for control cabinet; measuring range (10% ~ 100% of full‑scale range).
    Ripple Factor≤0.5%
    Voltage StabilityRandom fluctuation: ≤0.5% when mains voltage varies by ±10%
    Operation ModeIntermittent duty cycle, less than 30 minutes under rated load
    Operating ConditionsTemperature: 0‑40℃, humidity <90%
    Storage ConditionsTemperature: ‑10℃~40℃, humidity <90%
    AltitudeBelow 3000 m

    Overall Dimensions = Equalizing Shield Diameter (R) * Insulating Cylinder Diameter (r) * Overall Height (H)

    • Registered address: Room 302, Building 6, Baoding Zhongguancun Digital Economy Industrial Park, 777 Lixing Street, Gaokai District, Baoding City, Hebei Province

    • Mobile:+86-152-000-51135 (working hours)
                  +86-137-2296-5163 (off hours)
                  +86-136-6330-3815
      Online:+86-312-3156390/3155390

    • Marketing internal email: tzydq_yxb@163.com
      Technical Email: tzydq_jsb@163.com

    Copyright © Hebei Taizhongyan Electrical Equipment Technology Co., Ltd https://www.tzydq.com/ All Rights Reserved  Record number:冀ICP备13014722号-1    Friendship links: Optoelectronic Materials Division   Distribution Monitoring Division  
    HomeTelProduct