TZY-ZGF1000A Intelligent DC High Voltage Generator Series
Add time:2022-02-15
Page views:113
Dial +86-312-3156390 / 3155390Intelligent DC high voltage generator, the main function of this product is to output negative DC high voltage, with good voltage stability and high accuracy. It is an essential product for preventive testing and DC insulation withstand voltage testing. The product is widely used in preventive testing and research institutes of power generation and supply departments, transmission and transformation engineering companies, and large factories and mines.
1. The instrument is controlled by a microcontroller, with a 192 * 64 dot matrix Chinese menu, yellow green backlight, and clear display under sunlight.
2. The software can automatically complete the test by setting the test voltage, protection voltage, and test duration.
3. It has functions such as overvoltage protection, overcurrent protection, disconnection protection, non-zero start, grounding detection, and overload protection.
4. It has clock calendar display and environmental temperature and humidity detection functions.
5. It can store 200 sets of test data, which can be directly printed or exported to a USB flash drive. The data is exported in TXT format in table format and can be printed directly on a computer.
6. RS232 communication interface with high voltage isolation, capable of remote control.
7. The anti surge ammeter and the host have wireless communication function, and the ammeter data can be directly displayed on the host.
8. It has automatic testing, 10 step testing, manual testing, and automatic testing functions for zinc oxide lightning arresters.
9. Unique capacitive test sample automatic boost mode to avoid overcurrent and interruption of testing.
10. Using a digital potentiometer with 7 selectable step voltages:
60-160kV equipment (0.05kV, 0.1kV, 0.2kV, 0.5kV, 1.0kV, 2.0kV, 5.0kV)
200-350kV equipment (0.1kV, 0.2kV, 0.5kV, 1.0kV, 2.0kV, 5.0kV, 10kV)
11. Wide power supply voltage input: AC165V-245V, 50-60HZ.
12. The high-voltage doubler adopts DuPont material all solid packaging to avoid insulation problems caused by air and oil filled equipment. The wide base has a smooth outer cylinder, which is stable and easy to maintain.
13. Double ground wire: There is one ground wire inside the output control line to ensure the connection between the host and high voltage, and to ensure the normal use of the system; There is also a separate ground wire terminal on the chassis shell panel to ensure the safety of testing personnel and equipment.
14. Comes with an embedded micro printer for easy printing and recording of data.
| Voltage kV / Current mA | Control Cabinet | High‑Voltage Multiplier Unit | |||
| Rated Voltage | Overall Dimensions (mm) | Weight kg | Overall Dimensions (mm) | Weight kg | |
| 60/2‑10 | 60kV | 350 * 275 * 275 | 5kg | 470 * 260 * 220 | 6kg |
| 80/2‑10 | 80kV | 350 * 275 * 275 | 6kg | 490 * 260 * 220 | 8kg |
| 100/2‑10 | 100kV | 350 * 275 * 275 | 6kg | 550 * 260 * 220 | 8kg |
| 120/2‑10 | 120kV | 350 * 275 * 275 | 7kg | 600 * 260 * 220 | 10kg |
| 200/2‑5 | 200kV | 380 * 275 * 275 | 8kg | 1000 * 280 * 270 | 20kg |
| 250/2‑5 | 250kV | 380 * 275 * 275 | 8kg | 1130 * 290 * 270 | 20kg |
| 300/2‑5 | 300kV | 380 * 275 * 275 | 9kg | 1300 * 290 * 270 | 22kg |
| 350/2‑5 | 350kV | 380 * 275 * 275 | 9kg | 1370 * 290 * 270 | 24kg |
External dimensions=equal pressure cover diameter (R) * insulation cylinder diameter (r) * total height (H)
1. Negative polarity output, 1.1 times the rated voltage. The output ripple factor is less than 0.5%.
2. Working power supply: single-phase AC 165V~245V, 50-60HZ.
3. Rated output voltage: 120kV; Rated output current: 5mA, rated output power: 600W.
3. Measurement accuracy of host voltage: ± 0.5% ± 2 words, small resolution of 0.01KV, display 99999.
4. Measurement accuracy of host current: ± 0.5% ± 2 words, small resolution: 0.1 µ A; large display: 99999.
5. Measurement accuracy of anti surge ammeter: ± 0.5% ± 2 words, small resolution: 0.1 µ A; large display 9999.
Range: 0-5mA, 0-10mA, 0-20mA, factory standard configuration 0-5mA.
6. Working mode: Intermittent work for 30 minutes.
7. Voltage stability: Random fluctuations, ≤ 0.5% when the grid voltage changes by ± 10%.
8. Working conditions: temperature -10 ℃~40 ℃, humidity less than 90%.
9. Storage conditions: temperature -20 ℃~50 ℃, humidity less than 95%.
10. Altitude: ≤ 3000 meters.


86-312-3156390

冀公网安备 13065202000415号
Home
Tel
Product